TH 102 TRAINING BOILER, 200 kg/hr

Enquiry

Video

Download

This is a set of steam boiler and standard accessories for a study of boiler performance.

The basic unit consists of a small industrial type boiler with a burner, a feed water system, a fuel system, and instruments for monitoring boiler operation as well as instruments for control and safety. The complete unit is arranged as a package on a pallet for easy site installation. Optional equipment are available for additional experiments.

Instruction manual is also included.

  • Pressure, temperature and flow measurements.

  • Heat of combustion, heat given to steam and boiler        efficiency.

The boiler set consists of:    
  • Boiler unit:
    
- Type: Vertical, water tube   
- Rated output: Approx. 125 kW (107,800 kcal/h)   
- Equivalent evaporation: Approx. 200 kg/h steam   
- Maximum working pressure: 10 kg/cm2 (0.98 MPa)   
- Measuring instruments: Pressure gauge for steam outlet   
 : Temperature sensor for feed water, outlet steam and exhaust stack   
- Safety devices: Safety valve   
 : Low level alarm   
- Boiler accessories: Steam pressure regulator   
 : Steam separator   
 : Feed water pump   
 : Stack, 2x 2.4 m stainless steel with elbows   
  • Burner:
    
- Type: Forced draft, pressure atomized   
- Control: On-Off   
- Fuel: Diesel or kerosene (LPG is available as an option.)   
  • Fuel system
: Fuel tank (80 L), fuel meter and oil strainer   
  • Feed water system
: Resin filter for public water   
 : Soft water tank (200 L)   
 : Water meter   
 : Stopwatch   
  • Power supply
: 220 V, 1 Ph, 50Hz. Other power supply is available on request.   

Boiler Package

Net (unassembled) Shipping Dimensions WxLxH:

180 x 300 x 200 cm

Net Weight: Approx. 800 kg

Cooling Tower

Net (unassembled) Shipping Dimensions WxLxH:

110 x 110 x 150 cm

Net Weight: Approx. 95 kg

  • TH 101-013   Condenser (requires TH101-014, separately supplied)

Description

The unit is used for studying of heat transfer in a heat exchanger as well as recover condensate for reuse. The unit consists of a counter flow steam tube heat exchanger and instruments for measurement of temperatures, and cooling water flow rate.

Typical experiment

- Condenser heat transfer efficiency

Technical data

- Type: Steam tube
- Accessories: Cooling water pump
 : Condensate transfer pump
 : Condensate tank
 : Strainer
Measuring instruments 
- Water cooling flow rate: Water meter
- Sensor with digital displays: Temperatures for cooling water inlet and outlet
  • TH 102-014  
Cooling Tower (requires TH102-013, separately supplied)
Description 
 The unit is used for recovering of condenser cooling water as well as studying of cooling tower efficiency.
 The cooling tower is to recycle cooling water in case TH102-013 condenser is used.
 The unit consists of a cooling tower unit, a storage tank, a circulating pump and temperature gauges.
Typical experiment 
- Cooling tower efficiency 
Technical data 
- Cooling tower capacity: Up to 25 RT
- Circulating pump: 1.1 kW
Measuring instrument 
- Wet bulb temperature 
  • TH 100-021
Digital flue gas analyzer (testo300 or equal) for O2 and CO contents
  • TH 100-022
Portable pH and TDS meter
  • TH 100-023
Water Hardness tester
  • TH 101-021
Sand filter for water with suspended materials
  • TH 101-022
Carbon filter for water with odour or rust
SIMILAR PRODUCTS