HB 015 BERNOULLI’S THEOREM APPARATUS

Enquiry

Video

Download

Bernoulli’s theorem is applied on flow through a clear acrylic Venturi tube. The apparatus is to be used with Hydraulics Bench i.e. HB100 or HB100N (separately supplied) for a water supply and flow measurement.
Static pressures at various points along the wall of a transparent Venturi tube are directly measured on a manometer equipped with a vent valve. A movable stainless steel total head probe is also provided. Flow through the Venturi tube is controlled by a valve at the outlet. As a primary flow measuring device, coefficient of discharge for the Venturi tube can also be determined.
Instruction manual is also included.

  • Application of the Bernoulli equation
  • Measurement of the meter coefficient of discharge at various flow rates
  • Comparison of experimental results with theoretical predictions
  • Diameters
:  28 mm inlet with 14 mm throat   
  • Water manometer
:  8 tubes   
  • Total head probe
:  1   

 

  • Net (unassembled) Shipping Dimensions WxLxH   :  36 x 60 x 83 cm
  • Net Weight                                                                           :  Approx. 6 kg
HB011S: Learning Software to support both online/offline training with data   calculation and analysis by manual data entry from analog measuring instruments.
HP 011:  Pressure digital display

HB 011-002:  Additional calibration pressure gauge Class 1 with connection.
  
HB011S : Learning Software to support both online/offline training with data   calculation and analysis by manual data entry from analog measuring instruments.
SIMILAR PRODUCTS